Modell ONS-S-UCD-M006
|
Spezifikationen | |||
---|---|---|---|
Technical Specifications | |||
Maximum Input Frequency | 2 Hz (2 pulses per second) | ||
Measurement Range | 0 - 65,533 pulses per logging interval | ||
Resolution | 1 pulse | ||
Lockout time | 327 ms ±10% | ||
Recommended Input Type | Mechanical contact closure (example: reed switch in a tipping-bucket rain gauge) | ||
Preferred Switch State | Active low input Normally open | ||
Edge Detection | Falling edge, Schmitt Trigger buffer (logic levels: low ≤0.6 V, high ≥2.7 V) | ||
Minimum Pulse Width | 1 ms | ||
Input/Output Impedance | 100 kΩ | ||
Open Circuit Input Voltage | 3.3 V | ||
Maximum Input Voltage | 3.6 V | ||
Operating Temperature Range | -40° to 75°C | ||
Bits per Sample | 16 | ||
Number of Data Channels | 1 | ||
Measurement Averaging Option | No (reports the number of pulses over the logging interval) | ||
Physical Specifications | |||
User Connection | 24 AWG wires, 2 leads: white(+), black(-) | ||
Overall Cable Length | 6.5 m | ||
Housing | Weatherproof PVC housing protects input adapter electronics | ||
Housing Dimensions | 14 x 0.95 cm | ||
Weight | 310 g |