Modell ONS-UX120-017M

  • Vierkanal-Datenlogger zur simultanen Aufzeichnung von
    Pulsen, Zuständen, Ereignissen und Laufzeiten
  • Speichert bis zu 4 Millionen Einzelwerte
  • Pulsrate bis zu 120 Hz
  • Pulsamplitude 0 … 24 VDC
  • Schneller Datendownload über USB
  • Ausschließlich für den Inneneinsatz
Angebot anfordern

The HOBO 4-Channel Pulse Input data logger records electronic pulses and mechanical or electrical contact closures from external sensing devices. Using HOBOware®, you can easily configure each of its four channels to monitor and record pulse, event, state, or runtime data in a wide variety of applications, including tracking building energy consumption, monitoring mechanical equipment, and recording water and gas flow rates. Plus, when combined with the E50B2 Energy & Power Meter (T-VER-E50B2), this logger provides extensive power and energy monitoring capabilities.


Spezifikationen
Inputs
External Contact InputElectronic solid state switch closure or logic driven digital signals to 24 V
Maximum Pulse Frequency120 Hz
Maximum State, Event, Runtime Frequency1 Hz
Bits4-32 bits depending on pulse rate and logging interval
Maximum Pulses Per Interval7,863,960 (using maximum logging rate)
Driven Logic SignalInput Low: ≤0.4 V
Input High: 3 to 24 V
Absolute Maximum RatingMaximum Voltage: 25 V DC
Minimum Voltage: -0.3 V DC
Solid State Switch ClosureInput Low: <10 kΩ
Input High: >500 kΩ
Internal Weak Pull-Up100 kΩ
Input ImpedanceSolid state switch closure: 100 kΩ pull up
Driven signal: 4.5 kΩ
Minimum Pulse WidthContact closure duration: 500 µs
Driven logic signal: 100 µs
Lockout Time0 to 1 second in 100 ms steps
Edge DetectionFalling edge, Schmitt Trigger buffer
Preferred Switch StateNormally open or Logic "1" state
Logging
ResolutionPulse: 1 pulse
Runtime: 1 second
State and Event: 1 State or Event
Logging Rate1 second to 18 hours, 12 minutes, 15 seconds
Time Accuracy±1 minute per month at 25°C
Battery Life1 year typical with logging intervals greater than 1 minute and normally open contacts
Battery TypeTwo AA alkaline or lithium batteries
Operating RangeLogging: -40° to 70°C, 0 to 95% RH (non-condensing)
Launch/Readout: 0° to 50°C per USB specification
Memory
Memory4,124,672 measurements (assumes 8-bit)
Download TypeUSB 2.0 interface
Download Time1.5 minutes
Physical Specifications
Weight149 g
Size11.4 x 6.3 x 3.3 cm
Environmental RatingIP50


Broschüre
Betriebsanleitung
PDF Download - 275 KB

Datenlogger > Datensammler und Software
ModellBeschreibungEinsetzbar mit
ONS-BHW
  • Software HoboWare 3.0 für Windows/MAC
  • kostenlose Einstiegsversion
  • Allen Onset-Datenloggern außer Serien U20, U24, U26
ONS-BHW-PRO-CD
  • Software HoboWare Pro 3.0 für Windows/MAC
  • inkl. USB-Verbindungskabel
  • Allen Onset-Datenloggern

Datenlogger > Inneneinsatz
ModellAnzahl KanäleMess-/Überwachungs­größeMess-/Über­wachungs­bereichMesswerte/Status­wechsel
ONS-UX120-017
  • 4
  • Pulse
  • Zustände
  • Ereignisse
  • Laufzeiten
 
  • 520.000
ONS-UX90-001M
  • 1
  • Status-/Ereigniswechsel über ext. Kontakt oder Magnet
 
  • 346.795
ONS-UX90-002M
  • 1
  • Status-/Ereigniswechsel über int. Lichtsensor
 
  • 346.795
ONS-UX90-004M
  • 1
  • Status-/Ereigniswechsel über int. Magnetfeldsensor (Motor an/aus)
 
  • 346.795
ONS-UX90-005M
  • 1
  • Status-/Ereigniswechsel über int. Bewegungs- und Lichtsensor
  • 5 Meter
  • 346.795
ONS-UX90-006M
  • 1
  • Status-/Ereigniswechsel über int. Bewegungs- und Lichtsensor
  • 12 Meter
  • 346.795

Newsletteranmeldung