Modell SET-290

  • Robust Non-Liquid Filled Capacitive Sensor
  • Designed for Clean-In-Place (CIP) and Sterilize-In-Place (SIP) Installations
  • Meets 3A Sanitary Standards
  • 0.20% Full Scale Accuracy Improves System Performance
  • High Overpressure Protection
  • Insensitive to Thermal Shock
  • Industrial Design and 316 Stainless Steel Permits Use in Harsh Environments
Angebot anfordern

The 290 design meets 3-A sanitary design standards and is fully sealed to withstand external high pressure washdown and CIP/SIP cycles. As a totally self-contained electronic package, the 290’s capacitance sensing element, coupled with a signal conditioned IC-based circuit, assures excellent accuracy and long term stability.

The 290 pressure transmitter is intended for low to high pressure measurements of gases or liquids in sanitary applications. The 290 pressure transmitter, packaged in a rugged welded stainless steel housing, is exceptionally insensitive to vibration, shock and environmental extremes. Its small size, light weight, and tri-clover sanitary pressure fitting allows direct mounting in most CIP and SIP installations.

Unlike fluid-filled sensors, the 290 utilizes a rugged, non-filled capacitive sensor which enables low hysteresis and excellent performance during thermal transients.


Spezifikationen
Performance Data
2" Tri-Clover Sanitary Fitting
Accuracy RSS
(at constant temp)
±0.20% FS[1]
Non-Linearity (BFSL)±0.17% FS
Hysteresis0.10% FS
Non-Repeatability0.025% FS
Temperature Compensated Range-7 to +82°C
Thermal Zero/Span Shift1.8 %FS/50°C
Response Time10 milliseconds
EMI/RFI Effect<1.0% output shift; 10V/M, 10-300 MHz
Clamping Effect, Zero/Span Shift±0.15% FS
Maximum Vacuum (without affecting specifications)Half on ranges =15 PSI
Performance Data
1.5" Tri-Clover Sanitary Fitting
Accuracy RSS
(at constant temp)
±0.20% FS[1]
Non-Linearity (BFSL)±015% FS
Hysteresis0.12% FS
Non-Repeatability0.10% FS
Temperature Compensated Range-7 to +82°C
Thermal Zero/Span Shift1.8 %FS/50°C
Response Time10 milliseconds
EMI/RFI Effect<1.0% output shift; 10V/M, 10-300 MHz
Clamping Effect, Zero/Span Shift±0.25% FS
Maximum Vacuum (without affecting specifications)Full on ranges =30 PSI
Physical Description
Zero/Span AdjustmentsTop Access Through Seal Screws
CaseStainless Steel
Electrical Connection1/2" NPT Conduit Fitting & Strain Relief w/ 15ft Shielded Cable
Pressure Fitting2" or 1.5" Tri-Clover Sanitary Fitting
SanitaryMeets 3-A Sanitary Standard (74-02)
VentThrough Cable
Weight (Approx.)8 Ounces
Electrical Data
Circuit2-Wire
Output4 to 20 mA
Zero/Span Adjustment±0.5 mA
External Load0 to 800 ohms
Min. Supply Voltage (VDC)12 + 0.02 x resistance of receiver plus line
Max. Supply Voltage (VDC)30 + .004 x resistance of receiver plus line
Environmental Data
Operating Temperature-40 to +125°C[5]
Storage Temperature-55 to +125°C
Vibration10g, 50-1000Hz
Acceleration10g maximum[6]
Shock50g operating
Thermal Shock
(negligible shift)
0 to +125°C

Hinweise
[1]RSS of Non-Linearity, Non-Repeatability and Hysteresis.
[2]Units calibrated at nominal 70°F. Maximum thermal error is computed from this datum. Variations in the power supply voltage cause less than 0.005 mA change in the transmitter’s current output, per volt change in the power supply. Reverse excitation will not damage circuit.
[3]Calibrated at factory with a 24 VDC loop supply voltage and a 250 ohm load.
[4]Zero output factory set to within ±0.08mA.
Span (Full Scale) output factory set to within ±0.16mA.
[5]Operating temperature limits of the electronics only. Pressure media temperatures may be considerably higher or lower.
[6]shift in output reading at <0.05% FS/g; pressure port axis only.