Modell SET-209 / SET-209H

  • Kapazitiver Druckmessumformer für industrielle Anwendungen
  • Hohe Überdruckfestigkeit
  • Robustes Gehäuse
  • Großer Arbeitstemperaturbereich
  • Medienberührende Komponenten aus Edelstahl 316L (Modell 209H)
  • Einsatz in aggressiven Medien wie Wasserstoff möglich (Modell 209H)
  • Hohe Genauigkeit von ±0,25 % FS
Angebot anfordern

The Model 209 pressure transducer is designed for industrial applications with demanding price and performance requirements. The 209 offers exceptional reliability in typical industrial grade environments. Standard features tailor the Model 209 for applications with more extreme environmental conditions or more stringent performance needs. The Model 209 offers unparalleled performance in a configurable transducer designed specifically for the budget conscious OEM.

Setra’s proven center mount electrode configuration is the heart of this simple, yet industrialized design. A 17-4 Stainless steel sensor and a rigid stainless steel electrode form the variable capacitor.

The 209 transducer is packaged in a rugged stainless steel valox housing, which is small and lightweight for optimum compatibility with system designs. As a totally self-contained package, the 209 stainless steel capacitance sensing element, coupled with a high level output IC-based circuit, assures excellent accuracy and long term stability.


Spezifikationen
Performance Data
Accuracy RSS (at constant temp)±0.25% FS[1]
Non-Linearity, BFSL±0.22% FS
Hysteresis0.10% FS
Non-Repeatability0.05% FS
Thermal Effects
Compensated Range-20 to +80°C
Zero Shift±1.8 %FS/50°C
Span Shift±1.3 %FS/50°C
Warm-up Shift0.1% FS Total
Response Time5 milliseconds
Long Term Stability0.5% FS/1 YR
Environmental Data
Operating Temperature-40 to +85°C[3]
Storage Temperature-40 to +85°C
Shock200g operating[3]
Acceleration10 g Maximum[5]
Vibration20g[4]
Environmental ProtectionWeather Resistant
Pressure MediaLiquids and gases compatible with 17-4 PH Stainless Steel.[2]
Physical Description
CaseStainless Steel & Valox
Sensor17-4 PH Stainless Steel
Electrical Connection2 ft. multiconductor cable
Pressure Fitting1/4"-18 NPT external, 17-4 PH Stainless Steel[5]
VentThrough cable
Weight (approx.)65 grams
Electrical Data (Voltage)
Circuit3-Wire (COM, OUT, EXC)
Excitation9 to 30 VDC
Output0.5 to 5.5 VDC[6][7]
Output Impedance10 ohms
Electrical Data (Current)
Circuit2-Wire
Output4 to 20mA[8][9]
External Load0 to 800 ohms
Minimum supply voltage (VDC)9 + 0.02 x (Resistance of receiver plus line)
Maximum supply voltage (VDC)30+ 0.004 x (Resistance of receiver plus line).

Hinweise
[1]RSS of Non-Linearity, Hysteresis, and Non-Repeatability.
[2]Note: Hydrogen not recommended for use with 17-4 PH Stainless Steel.
[3]Mil-Std. 202, Method 213B, Cond. C
[4]Mil-Std. 202, Method 204, Cond. C
[5]See sec sheet for other fittings available (minimum quantities apply).
[6]Calibrated into a 50K ohm load, operable into a 5000 ohm load or greater.
[7]Zero output factory set to within ±50mV. Span (Full Scale) output factory set to within ±50mV.
[8]Calibrated at factory with a 24 VDC loop supply voltage and a 250 ohm load.
[9]Zero output factory set to within ±0.16mA. Span (Full Scale) output factory set to within ±0.16mA.