Modell SET-231

  • Field Selectable Output
  • True 4 to 20 mA Output and 0-5, 1-5, and 0-10 VDC Output
  • Field Selectable Pressure Ranges
  • Field Accessible Push-Button Zero and Remote Zero
  • Dual Sensors
  • Field Selectable Port Swap
  • Optional LCD Display
  • All Cast Aluminum, NEMA 4 Rated Housing
Angebot anfordern

Setra’s Model 231 Multi-Sense Wet-to-Wet differential pressure transducer all-inclusive design provides users with field accessible ranging, choice of output and field zeroing.

Choose from three configurable pressure transducers: 5 up to 50 psid, 10 up to 100 psid, or 25 up to 250 psid. Each Model 231 has 4 unidirectional and 4 bidirectional switch selectable pressure ranges and can be reconfigured in the field for 0-5 VDC, 1-5 VDC, -0-10 VDC, or 4 to 20 mA output. The Model 231 jumper selectable port swap feature eliminates costly replumbing if the pressure transducer is improperly installed or replaced. An optional LCD display is available for on-site indication of line and differential pressure.


Spezifikationen
Performance Data
Accuracy RSS (at constant temp.)
Pressure Ranges A, B, C
Pressure Range D

±1.0% FS
±2.0% FS
[1]
Pressure Ranges (MS1)Range A: 50 psid
Range B: 25 psid
Range C: 10 psid
Range D: 5 psid
Max. Line Pressure: 50 psig
Pressure Ranges (MS2)Range A: 100 psid
Range B: 50 psid
Range C: 20 psid
Range D: 10 psid
Max. Line Pressure: 100 psig
Pressure Ranges (MS3)Range A: 250 psid
Range B: 125 psid
Range C: 50 psid
Range D: 25 psid
Max. Line Pressure: 250 psig
Compensated Temperature Range0 to +54°C
Thermal Zero/Span Shift1.8 %FS/50°C[2]
Warm-up Shift<0.12% FS
Response Time1 to 5 sec. (selectable)
Proof Pressure2 x Full Scale
Burst Pressure15 x Full Scale (50 psi), 10 x Full Scale (75 x 150 psi), 8 x Full Scale (250 psi)
Environmental Data
Operating Temperature-20 to -85°C[3]
Storage Temperature-20 to +85°C
Vibration10g from 50Hz to 2000 Hz
Shock200g
Pressure MediaLiquids or Gases Compatible with 17-4 PH Stainless Steel
Note: Hydrogen not recommended for use with 17-4 PH stainless steel
Electrical Data (Voltage)
Circuit3-Wire
Excitation15 to 30 VDC/18 to 30 VAC (Reverse Excitation Protected)
Output0 to 5 VDC, 0 to 10 VDC, 1 to 5 VDC[4]
Output Impedance30 Ohms
Circuit Consumption8 mA (typ.) at 5 VDC,
8 mA (typ) at 10 VDC,
40 mA (typ.) at 18-30 VAC
Electrical Data (Current)
Curcuit2-wire (Reverse Excitation Protected)
Output4 to 20 mA[5]
External Load0 to 250 Ohms
Min. Supply Voltage (VDC)15 + 0.02 x (Resistance of reciever plus line).15 + 0.02 x (Resistance of receiver plus line).
Max. Supply Voltage (VDC)30 + 0.004(Resistance of reciever plus line).30 + 0.004 x (Resistance of receiver plus line).

Hinweise
[1]RSS of Non-Linearity, Hysteresis, and Non-Repeatability.
[2]Units calibrated at nominal 70°F. Maximum thermal error computed from this datum.
[3]Operating temperature limits of the electronics only. Pressure media temperatures may be considerably higher or lower.
[4]Calibrated into a 50K ohm load, operable into a 5000 ohm load or greater.
[5]Calibrated at factory with a 24 VDC loop supply voltage and a 250 ohm load.


Broschüre
Produktinformation
PDF Download - 456 KB

Broschüre
Operating Instructions
PDF Download - 1.004 KB
Newsletteranmeldung